Home

The first
OPEN
middle ear diagnostics device

Quick.
Non-invasive.
Objective.

FASTER

Testing speed is crucial with children and other sensitive subjects. Just a few seconds per ear and it’s all over.

EASIER

Preparing the subject and choosing the right tip is quick and easy.

NON-INVASIVE

Testing creates no disturbance, no annoying sensation of clogging inside the ear.

PAINLESS

No pressure = No pain!
med·wave® permits testing even when ear inflammation or pathologies are present.
This makes it particularly suited for use with children or whenever pain is present.

From conventional "closed" technology to innovative "open" technology

The first painless revolution in more than 50 years in pediatric middle ear diagnostics.

Conditions in the middle ear are still often analysed using instruments with serious limitations; some require the insertion of acoustic couplers in the external ear canal, while selecting and exactly testing the size and shape of the “tip” for the tightest seal against positive and negative pressure can take entire minutes.

The alternative includes otoscopy and a visual check-up without testing ear function. It’s fast, but the results are subjective and cannot be compared with other data.

med·wave® is the first painless revolution in more than 50 years of middle ear diagnostics; med·wave® is the OPEN device for middle ear assessment based on patented PLAI® (Pressure Less Acoustic Immittance) methodology.
A new, non-invasive and objective middle ear analysis method that takes only seconds.
A clean break with the technologies of the past.

med·wave® takes the first step in a new direction as a device “open” to innovation, new standards, new users, and accessible to one and all.

Using such an innovative device has never been so easy


NEW Built-in WI-FI connection!
Connection to local wi-fi networks makes it easy to consult, save, and print clinical reports directly on your pc/tablet or another device!
User Interface
Easy to use even when performing examinations in upright position.

Highly reactive touchscreen
permits quick and easy data entry. The operator uses the touchscreen to control every function in the various phases of examination, diagnosis, and test reporting for a smooth and ideal workflow.

OPEN technology eliminates the need for pressure changes inside the ear canal.

Highly specific and sensitive diagnosis suggestions are useful for both research and screening.

Innovative design Rounded edges and no keys ensure highest levels of hygiene and ergonomics.

Probe
Testing begins automatically as soon as the probe is positioned correctly at the external ear canal.

External keypad*

The device can be connected to an external keypad for easier data input and reading.
* Compatible keypads:
– HP ku-1469
– Perixx Periduo 212
– Check compatibility of other keypads with Neuranix


The med∙wave® device is based on PLAI® methodology patented by Neuranix.
Device switch-on
We all know how precious time is. No one can afford to waste it.
Software innovations now let you switch on the device in little more than 20 seconds at the start of the working day.
Quick tests
From entering patient data to consulting results takes little more than a minute.

Compare exams
View multiple examinations performed on the same patient over time to monitor the healing process.


med·wave® test results
All test results can be downloaded, exported, and printed right after the analysis in the dedicated section.
Handy. Lightweight. Portable.
Take it from one studio to another.
Test anytime, anywhere, under any conditions.

Using such an innovative device has never been so easy



Built-in WI-FI connection NEW!

Connection to local wi-fi networks makes it easy to consult, save, and print clinical reports directly on your pc/tablet or another device!

Handy. Lightweight. Portable.
Take it from one studio to another. Test anytime, anywhere, under any conditions.
Highly reactive
touchscreen

permits quick and easy data entry. The operator uses the touchscreen to control every function in the various phases of examination, diagnosis, and test reporting for a smooth and ideal workflow.

User interface

Easy to use even when performing examinations in upright position.

OPEN technology eliminates the need for pressure changes inside the ear canal.

Highly specific and sensitive

Diagnosis suggestions are useful for both research and screening.

Innovative design Rounded edges and no keys ensure highest levels of hygiene and ergonomics.

Probe

Testing begins automatically as soon as the probe is positioned correctly at the external ear canal.


External keypad*

The device can be connected to an external keypad for easier data input and reading.
* Compatible keypads:
- HP ku-1469
- Perixx Periduo 212
- Check compatibility of other keypads with Neuranix

The med∙wave® device is based on PLAI® methodology patented by Neuranix.

Device switch-on

We all know how precious time is. No one can afford to waste it. Software innovations now let you switch on the device in little more than 20 seconds at the start of the working day.

Quick tests

From entering patient data to consulting results takes little more than a minute.


Compare exams

View multiple examinations performed on the same patient over time to monitor the healing process.


med·wave® test results

View multiple examinations performed on the same patient over time to monitor the healing process.

Why Specialists choose med·wave®

QUICK

The device is easy to handle, quick, and simple to use: the test is completed in less than 2-3 seconds per ear.

NON-INVASIVE

Patients remain comfortable: the test is non-invasive and painless even when the ear is sensitive or inflamed.

OBJECTIVE

Testing is accurate, repeatable and objective in both analysis and suggestions for diagnosis.

The best choice for:

AUDIOLOGISTS

NEONATOLOGISTS

PEDIATRICIANS

ENT DOCTORS

When is med·wave® best indicated for use at hearing aid centers?

Before taking a middle ear imprint prior to fitting a hearing aid, med·wave® can become a vital step in the hearing center’s middle ear assessment protocol. Testing before fitting also helps audiologists make sure there are no other problems.

When checking that no inflammation or occlusion is present in the ear canal.
med·wave® permits assessment of conditions in the eardrum and middle ear without any pain at all, even when inflammation is present. After therapeutic intervention, it can provide indication of whether an acute phase or improvement is likely.

For exclusion of perforation
Otoscopy does not always detect minute perforations; med·wave® testing can be performed for greater assurance, without worry, because no change in pressure is required.

With pediatric patients
med·wave® makes testing pediatric patients quick, easy and painless because it takes only 2-3 seconds!

The best way for quick, safe, reliable test results

PLAI® methodology and med·wave® technology are breakthroughs in the way middle ear assessment is conducted and checked. The development of a system that enables acoustic immittance testing without requiring positive or negative changes in eardrum pressure makes all the difference in the world for sensitive patients.

Experienced practitioners* discourage performing tympanometry on subjects after eardrum surgery, even on those with only suspected lacerations. No such restrictions apply to med·wave®, which is safe and reliable for these types of patient.
Reliability also means speed, safety, objectivity.
med·wave® is all this and more.

*White paper: “Pros and cons of traditional tympanometry: the customer voice”- Dott.ssa Flavia Sorrentino-Dott. Marco Greggio,September 2022

The best way for quick and reliable screening from the child’s first days of life

Screening an infant’s hearing is particularly important in ensuring his or her correct development and future language ability, education, and social integration.
Undetected or mistakenly diagnosed hearing problems can lead to major problems for the child in all three areas above.
Accurately identifying present and potential hearing problems and intervening as soon as possible therefore assumes paramount importance.

Simple and clear test result interpretation.

The dashboards permit rapid display of the results of tests performed on infants 0-24 months old.

med·wave® test report

PASS Result: considered compatible with healthy ear conditions.

REFER Result: Health conditions should be assessed in greater detail through more specific diagnostic exams.

Using med·wave® in newborn screening

med·wave® can play a key role in newborn screening?

Newborn screening can provide misleading indications due to the presence of liquid or material in the external ear canal or tympanic cavity. In these cases, the failure of the tests is not ascribed to neurological causes of hearing loss but rather a decrease in hearing of conductive causes.
Acoustic impedance measurement using med·wave® conducted after OAE or ABR tests that reads REFER suggests the advisability of checking the middle ear’s auditory transmission potential, in this way improving screening specificity and reducing initial uncertainty in diagnosis. Another measurement requiring just a few seconds one or two weeks before the next visit to the specialist can be proposed to make sure that a common transmission problem is no longer present.

Included as a regular part of the screening protocol, med·wave® helps caregivers identify ear problems in PASS/ REFER mode: any value that is not awarded a PASS result must be investigated in successive and multiple specialist visits, this offers an additional possibility of evaluation in the verification phase of subjects under 24 months of age.

When best indicated for use by doctors and patients

Audiological assessment
med·wave® can be used during routine examinations at pediatric clinics and assess eardrum and middle ear status.

Pediatric assessment
Testing with med·wave® when compiling the child’s health record provides a “snapshot” of the real conditions in the middle ear at the time for comparison during subsequent check-ups or whenever symptoms of otitis media appear.

Inflammation
med·wave® permits non-invasive eardrum and middle ear status assessment. Subsequently it indicates worsened or improved conditions following pharmacological treatment.

Suspected perforation
Thanks to the absence of painful changes in pressure, med·wave® testing poses no risk when perforation is suspected after otoscopic evaluation, accurately indicating whether perforation is present or not.

The best way for quick, safe, reliable test results

Simple and clear test result interpretation.

The dashboards let the Pediatrician consult the results of the test performed quickly.

med·wave® test report

Normal ear eardrum function is adequate.

The eardrum appears to be more flaccid than normal Possibility of eardrum perforation

Stiffened eardrum compatible with the presence of Otitis media.

When is med·wave® best indicated for medical use?

Diagnostic instruments of the past were highly complex due to unsurpassable technical limitations. Today, for caregivers at every level and patients alike, med·wave® improves and simplifies both routine check-ups and investigations of whether acute tympanic phases are in progress or not. Lightweight and compact, efficient and self-contained, assistance in diagnosis is guaranteed even when moving from one clinic to another.

No change in normal eardrum pressure makes measurement painless for patients when pathologies are present. PLAI® methodology permits acoustic admittance measurement even when tympanic perforation is suspected and offers precious aid in monitoring post-surgery healing processes.

The best way for quick, safe, reliable test results

PLAI® methodology and med·wave® technology are breakthroughs in the way middle ear assessment is conducted and checked. The development of a system that enables acoustic immittance testing without requiring positive or negative changes in eardrum pressure makes all the difference in the world for sensitive patients.

Experienced practitioners discourage performing tympanometry on subjects after eardrum surgery, even on those with only suspected lacerations. No such restrictions apply to med·wave®, which is safe and reliable for these types of patient.
Reliability also means speed, safety, objectivity. med·wave® is all this and more.

*White paper: “Pros and cons of traditional tympanometry: the customer voice”- Dott.ssa Flavia Sorrentino-Dott. Marco Greggio,September 2022

Capitale sociale 22.857,30 € I.V.
Registro imprese di Napoli NA-971341